UNDER CONSTRUCTION
Radiated Immunity
1008 Magnetic immunity test system  |
|


|
The PMM 1008 is an integrated system for magnetic field immunity test according to IEC 1000-4-8 & EN 61000-4-8.
The system is composed by PMM 1008/1 (programmable current
generator) and a loop antenna that is available in different sizes to
select according to the EUT dimensions:
- 1008/2: square loop antenna, 1x1 m
- 1008/3: square loop antenna, 1,5x1,5 m
- 1008/4: square loop antenna, 2x2 m
- 1008/5: rectangular loop antenna, 2,6x1 m
One or two masts – according to the size – allow for positioning up and down and rotate the loop antenna.
The generator features output current sensing to control the
stability of the magnetic field produced by the loop antenna respect to
variations due to cable heating, connections and power line
fluctuations.
An audible alarm is generated during the test to warn the user.
Product description : 
|
3030 - EMC Wide Band RF Generator, 9 kHz - 3 GHz  |
3010 - EMC Wide Band RF Generator, 9 kHz - 1 GHz  |
 |
PMM 3030 is a powerful wide band signal generator,
ideal for all EMC immunity test applications that has been designed
adopting an innovative philosophy and state-of-art components. The model
equipped with plug-in, rechargeable battery pack allows for ground
loops-free operation and true portability. PMM 3030 features a
particularly user-friendly interface based on a clear, bright display
and function keys conveniently arranged. All settings can be done by the
front panel keyboard and rotary knob.
MAIN FEATURES
- PMM 3030 9 kHz to 3 GHz frequency range
- PMM 3010 9 kHz to 1 GHz frequency range
- -107 to +10 dBm RF output
- Internal AM and pulse modulation
- Battery operation (mod. 3030-02)
- RS232/USB communication
- GPIB with external adapter
Product description : 
|
|
SPECIFICATIONS
|
PMM 3030
|
|
Frequency range
|
9 kHz – 3 GHz
|
|
Frequency resolution
|
1 kHz
|
|
Frequency accuracy
|
± 10 ppm
|
|
Level range
|
-107 to +10 dBm
|
|
Level resolution
|
0.1 dB
|
|
Level accuracy
|
± 1 dB, level > -30 dBm
|
|
Output impedance
|
50 ohm
|
|
RF output connector
|
N female
|
|
Spectral purity -harmonic
|
< -30 dBc @ 0 dBm, f > 1 MHz
|
|
AM modulation, internal
|
2 – 50 – 400 Hz, 1 kHz; 10% to 90%
|
|
AM modulation, external
|
2 Hz to 10 kHz; 10% to 90%
|
|
Input impedance
|
600 ohm
|
|
Input connector
|
BNC female
|
|
Internal pulse modulation
|
1 Hz: ON/OFF ratio @ 0 dBm > 40 dB 200 Hz: ON/OFF ratio @ 0 dBm > 40 dB
|
|
Remote control
|
RS-232, USB 2.0 (rear), User Port GPIB (external adapter)
|
|
User Port
|
RF OFF, RF ON, Start/stop test
|
|
Display
|
340 x 240 pixels, 16 gray levels
|
|
Display units
|
dBm, dBuV
|
|
Operating temperature
|
+10°C ÷ +40°C
|
|
Power supply
|
DC 10 – 15 V, 2.5 A
AC – DC adapter 115 – 230 V 50/60 Hz
|
|
Plug-in Battery pack (model 3030-02)
|
Li-Ion, rechargeable 3 h operation time (avg)
|
|
Dimensions
|
235 x 105 x 335 mm (WxHxD)
|
|
Weight
|
3.5 kg (mod. 3030-01) 4.3 kg (mod. 3030-02)
|
|
6630 - USB RF Power Sensor, 9 kHz - 3 GHz  |
 |
Accurate in laboratory, fast in manufacturing and solidly build for field applications
PMM 6630 is the ideal solution for RF power measurements in a
wide variety of applications, including EMC immunity test systems to
calibrate CDN and Clamps as well as to measure the input power of
antennas or GTEM cells
Together with a directional coupler both direct and reflect power can be measured easily and precisely.
PMM 6630 is supplied with easy to use PC software to display the measurements in dBm, W, Vrms.
MAIN FEATURES
- 9 kHz to 3 GHz frequency range
- 100 nW to 1 W (-40 to +30 dBm) input range
- Excellent power linearity (0.2 dBm typical)
- True RMS response across 70 dB dynamic range enables accurate CW and modulated power measurements
- Low current consumption to save laptop battery
- No need for a Reference Calibrator
- Lightweight, convenient and easy to use with desktop and laptop PC
Product description : 
|
|
SPECIFICATIONS
|
6630
|
|
Frequency range
|
9 kHz to 3 GHz
|
|
Power measurement range
|
100 nW to 1 W
-40 to +30 dBm
|
|
Max. input power
|
2 W peak envelope max. 300 ms
|
|
Power linearity
|
0.2 dB (-40 to +30 dBm @ 50 MHz; 25 °C ± 10°C)
|
|
Measurement accuracy 1, 2
|
< 0.35 dB
|
|
Measurement path
|
High: +30 to -9 dBm
Low: -9 to -40 dBm
1 dB typ. switching point hysteresis
|
|
Max. SWR
|
10 ÷ 300 kHz: 1.10 +30 ÷ -9 dBm
>300 ÷ 100 MHz 1.05
>100 MHz ÷ 1 GHz 1.10
>1 ÷ 3 GHz 1.25
10 kHz ÷ 3 GHz 1.20 -9 ÷ -40 dBm
|
|
Operating temperature
|
-10°C ÷ +50°C
|
|
Power supply
|
5 VDC – 100 mA from USB port
|
|
RF connector
|
N male, 50 Ω
|
|
PC communication interface
|
USB 1.0 – 1.1 – 2.0
|
|
PC Software settings
|
N° of Averages (1 to 1024)
Offset
Correction Factor
|
|
Measuring units
|
dBm, W, Vrms
|
|
Dimensions
|
30 x 30 x 95 mm (WxHxP)
|
|
Weight
|
0.12 kg
|
1. Max. SWR of source: 1.25
2. Calculated with worst calibration uncertainities to the calibration factor of 0.17 dB
|
EP600 - EP601, Active electric field probe, 100 kHz - 9,25 GHz |
 |
The PMM EP600 active broadband electric field probe offers superior performances in the 100 kHz - 9,25 GHz frequency range, 0,14 - 140 V/m.
PMM EP601 10 kHz - 9,25 GHz 0,5 - 500 V/m.
Electric field probes combining excellent RF
characteristics from 10 kHz up to 9,25 GHz, wide range (0,14 - 140 V/m,
EP-600; 0,5 - 500 V/m, EP-601), small size, light weight (25 g only),
true spherical symmetrical configuration.
The advanced internal Li-Mn rechargeable battery
guarantees superior reliability with up to 80 hours of continuous
operation. PC direct connection via Optical to RS232/USB adapters, up to
40 m.
Suitable for all EMC/EMI applications (chambers and
TEM/GTEM cells), biology, materials research and wherever fast and
accurate measurements with negligible or minimum interference of the
probe to the field under measure are essential. Accredited calibration
provided.
Product description : 
|
Antennas  |
 |
|
Antennas
The range of PMM antennas covers most of the EMI/EMC
applications. Each antenna is individually calibrated. Up to 50 MHz the
monopole antennas are calibrated with the substitution method.
Loop antennas are calibrated inside an anechoic chamber by
measuring the current in a primary loop and calculating the induction
field; the loop antenna is placed in the known field and the antenna
factor is then measured.
Comprehensive antenna kits are available as cost-effective solutions, too.
|
PMM Immunity Suite Software  |
| |
PIMS - PMM Immunity Suite Software

The new "PMM Immunity Suite" (PIMS) software, accurately
designed in terms of functions and user friendly approach, can manage
the whole range of PMM components during both Test and Calibration
processes, introducing the possibility of looking at the various
monitoring tracks from generator, power meters and field sensors. The
software is user friendly and provides a really ergonomic configuration
which comfortably drives the operator through the various steps, from
definition and selection of HW components to settings of required
parameters and finally starting the test with "just one button".
Program window has been designed for omni-comprehensive overview of
each specific test being performed, so that operator can easily control
all details with a quick glance. A graphical scheme of the test set-up
clearly reminds about proper physical connections between components,
which could slightly differ between Tests and Devices' Calibrations.
In case of Radiated Immunity Tests according to IEC/EN
61000-4-3 in Anechoic Chambers or TEM/GTEM Cells, PIMS does also
include calibration of radiated field up to 16 points in the grid of
Field Uniformity assurance, providing "Amplifier Saturation Check"
routine for proper amplifier/antenna matching verification at 80% AM
Modulation increased power.
Product description : 
|
|
 |
| |
 |
|